<LOGO>
FM Transmitter Measurement Report
Created: 2025-11-01 20-42-40
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
93.20 MHz 5/5, 59 dBuV YLEX
Pilot RDS Phase Difference
7.2 kHz 2.3 kHz 69 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 63 kHz 19197 2,3545
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
1,9 dBr 3,39 dBr 5,0 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"YLEX " 6202 10 (Pop M) 0 1 1 1 20:42, 1.11.2025
RT
"YleX Dream: Lina Schiffer ja Taika Mannila (u) "
AF EON
91.5, 91.8, 91.9, 92.6, 93.2, 94.3, 96.1 MHz 6203, 6207, 6205, 6201
FM Scope Max at: 63 kHz MIN: 9 kHz % above 76 kHz: 2,3545 Acquired: 2025/11/01 20.41.36 Total samples: 19197 Equivalent time: 0:15:59 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 5,0 dBr MIN: 1,9 dBr AVE: 3,39 dBr % above 12,2 dBr: 0,0 Last value: 4,4 dBr (2025/11/01 20.41.35) 20.28 20.30 20.32 20.34 20.36 20.38 20.40 0 2 4 6 Pm [dBr]